PepDose

Methodology

How PepDose calculators are validated

Last validated November 12, 2026 · Methodology version 1.0

The PepDose calculators do one job: turn the numbers on a vial label into a syringe reading. This page shows the exact formulas, worked examples, the tests we run and the limits of the maths.

Arithmetic correctness is not dose advice. A calculator that is right about the maths still cannot tell anyone what dose is right for them. PepDose does not recommend doses. Talk to a licensed clinician about dosing, and check every number against your own vial label.

The formulas

All calculation happens in mg and mL. Syringe “units” use the U-100 insulin scale, where 100 units fill 1 mL and 1 unit is 0.01 mL.

concentration (mg/mL) = vial amount (mg) ÷ water added (mL)
draw volume (mL) = dose (mg) ÷ concentration (mg/mL)
units = draw volume (mL) × 100
doses per vial = vial amount (mg) ÷ dose (mg)
1 mg = 1,000 mcg · dose (mg) = dose (mcg) ÷ 1,000

The reverse calculator solves the other way round: concentration = dose (mg) ÷ (target units ÷ 100), then water (mL) = vial amount (mg) ÷ concentration. The units-to-mg converter is mg = (units ÷ 100) × concentration. The blend calculator applies the same concentration formula to each component in the vial; one draw volume fixes every component’s amount, and each component’s amount per dose is its own concentration × the draw volume.

The calculators that use these formulas: peptide reconstitution calculator, BAC water calculator, units to mg converter and blend calculator. They run in your browser; nothing you type is sent anywhere.

Worked examples

These numbers are computed by the same code the calculators use, every time this page is built.

1. Forward: how many units for this dose?

A 10 mg vial mixed with 2 mL of water is 5 mg/mL. A 250 mcg dose is 0.25 mg, so the draw is 0.25 ÷ 5 = 0.05 mL, which is 5 units. The vial holds 40 doses of that size.

2. A larger dose in mg

A 30 mg vial with 3 mL of water is 10 mg/mL. A 2.5 mg dose is 2.5 ÷ 10 = 0.25 mL = 25 units, and the vial holds 12 doses.

3. Reverse: how much water?

To draw 10 units for a 250 mcg dose from a 10 mg vial, the concentration must be 0.25 ÷ 0.1 = 2.5 mg/mL, so add 10 ÷ 2.5 = 4 mL of water.

4. Blend

A vial with 5 mg of Peptide A and 5 mg of Peptide B in 2 mL is 2.5 mg/mL of each. Drawing 10 units (0.1 mL) gives 250 mcg of each, and the vial holds 20 draws.

5. Rounding in action

A 7 mg vial with 2 mL of water is 3.5 mg/mL. A 250 mcg dose then needs 7.14286 units internally, shown as 7.14 units on screen. Real syringes can’t be read that finely, which is why the calculators show a small number of decimals.

Tests we run

The calculator code is covered by self-test scripts in the site’s repository, written as hand-worked cases and independent re-calculations. All were last run on 2026-11-12:

  • Core maths: 25 of 25 checks passed. Hand-worked forward, reverse, conversion and blend cases; unit mix-up warnings; mcg and mg agreement; and the empty-input error count.
  • Methodology checks: 19 of 19 checks passed. A grid of 216 vial, water and dose combinations compared with a separately written formula; the worked examples above; invalid inputs; every warning; and rounding.
  • Compound page data: 135 of 135 checks passed. Every page’s sources exist and are cited, links resolve, and the unit examples on the pages equal the formula above.

These tests check arithmetic and data consistency. They do not check whether any dose is appropriate for a person.

Invalid input and rounding

  • Zero, negative, blank or non-numeric values for the vial amount, water or dose are rejected with a plain message. The result is 0, never a guessed number, and never “NaN” or “Infinity”.
  • The blend calculator needs at least two components, an amount for each, and a water volume above zero.
  • Nothing is rounded during the calculation. Only the displayed numbers are rounded: units to 2 decimals below 10 units and 1 decimal above; concentration to 3 decimals; mg and mL figures to 2 or 3 decimals; amounts below 1 mg are shown in mcg.
  • Rounding is half-up with a small correction for floating-point error, so 2.675 shows as 2.68.

Warnings the calculators show

  • The draw is larger than the chosen syringe holds (0.3 mL = 30 units, 0.5 mL = 50 units, 1 mL = 100 units).
  • The draw is under 2 units, which is very hard to measure accurately.
  • One dose is more than the whole vial, or the dose is 10 mg or more. These catch a 1,000-times mix-up between mcg and mg.
  • More than 5 mL of water, which is unusual for a standard vial.
  • In the reverse calculator, water above 5 mL or below 0.5 mL.

What the maths does not cover

  • U-100 syringes only. U-40 and U-50 syringes have different markings, and the unit figures do not apply to them.
  • The label amount is taken as correct. The calculators assume the vial holds exactly what it says and that the powder adds no meaningful volume to the liquid. Real vials can be over- or under-filled, and the powder does take up a little space.
  • Syringe dead space and drawing losses are not modelled, and syringe markings have their own manufacturing tolerance.
  • Storage, stability and sterility are outside the calculators. Compound pages describe what the cited sources say about them.
  • Whether a dose is right for you is a medical question. The calculators work out the draw for any dose you type, and a number appearing on screen does not mean it is a sensible dose.

Version and corrections

This is methodology version 1.0, last validated 2026-11-12. When the calculator code changes, the tests are re-run and this page’s date and version are updated. If you find a result that disagrees with the formulas above, email support@pepdosecalculator.com with the numbers you entered. See the editorial policy for how corrections work, and about PepDose for who runs the site.